BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published July 8, 2025 at 8:00 PM

Updated July 9, 2025

Renovation of a mixed-use development in Lawrence, Kansas. Completed plans call for the renovation of a medical facility.

1. PURPOSE OF THE PROJECT The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and transoms for all (4) vestibules. 2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS o The interior and exterior doors shall be 42" wide to accommodate gurneys used by EMS and wide wheelchairs. o All exterior doors shall have a full window/daylight panel measuring approximately 34"x 69" and be UL 752 Level 5 bullet resistant glazing or equivalent. o All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door, transom, sidelights) shall be 1/4 " tempered glass. o The northwest corner of the building has an existing metal and glass vestibule protruding from the building measuring approximately 36" out from the building and 64" wide. The (2) panes of glass on the exterior vestibule measure approximately 30"x 90". These panes of glass shall be replaced with UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse exterior door measuring 42"x 84". The transom window shall be 4"x 42" and shall be 1/4" tempered glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway, shall be a left hand reverse door measuring 42"x 84" with (2) sidelights measuring approximately 8" x 100" and a transom measuring approximately 16" x 42". o The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door measuring 42"x 84" with (2) sidelights measuring approximately 14"x 100"and a transom measuring approximately 16"x 42". The interior door shall be a left hand reverse door measuring 42"x 84" with (2) sidelights measuring approximately 15"x 100" and a transom measuring approximately 16"x 42". o The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall have a right hand reverse exterior door measuring 42"x 84" with (1) sidelight measuring approximately 13"x 101" and a transom measuring approximately 17"x 42". The interior door shall be a right hand reverse door measuring 42"x 84" with (2) sidelights measuring approximately 5"x 100" and a transom measuring approximately 16"x 42". o The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42"x 84" with (2) sidelights measuring approximately 15"x 100" and a transom measuring approximately 17"x 42". The interior door shall be a left hand reverse door measuring 42"x 84" with (2) sidelights measuring approximately 15"x 100" and a transom measuring approximately 16"x 42". o Contractor shall coordinate with the facility's existing Secure Access Control provider (Cam-Dex Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes back to original locations or as close as possible for all replaced doors. Card readers and strikes shall be in good working order before starting on the next exterior door for security purposes and to justify egress. o Door and window frames shall be black anodized aluminum and match the fit and finish of the current frames. o All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar, heavy-duty continuous hinge with threshold, and lock keyed to the facility master key. o All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior, automatic sliding door entrance. Tinting shall be minimum of 35% shade. o All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover persons entering and exiting the building. The awnings shall be black anodized aluminum (or equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more than 36" away from the building. All awnings shall be equipped with gutters and downspouts to divert water away from the building. THE ESTIMATED MAGNITUDE OF THIS PROJECT IS BETWEEN $100,000.00 AND $250,000.00 Period of Performance: 07/28/2025 to 01/27/2026 *The value for this project is based on a financial range. The value is listed as the highest possible cost from the range provided by a stakeholder or official project document.

Post-Bid

Medical

$250,000.00

Public - Federal

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

2 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
168
Active Projects
95
Bidding Soon
1,151
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

July 7, 2025

July 28, 2025

Project location map

2415 Massachusetts St, Lawrence, KS


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.