BLOCK PAGE!!!
Get Full Details

Privately Funded

Bidding Soon

Documents Available

Publicly Funded

Addenda Available

Post-Bid

Published July 24, 2025 at 8:00 PM

Updated July 25, 2025

Renovation of a municipal facility in Micco, Florida. Completed plans call for the renovation of a municipal facility.

As of July 2, 2025 Project has not been awarded, Award will be on July 15, 2025 Question Deadline 06/16/2025 Questions about the meaning or intent of the RFP shall be submitted in writing and directed to The Office of the District Clerk, 625 Barefoot Blvd., Barefoot Bay, FL 32976, Attention: Cindy Mahalick, District Clerk. Questions may also be e-mailed to cindy.mihalick@bbrd.org The successful proposer will be responsible for obtaining all required design, engineering, and applicable permits for the project. A generalized summary of the project includes the following: o All required design, engineering and permitting o Lounge o Demolition and removal of existing walk in cooler o Demolition of existing concrete and installation of new concrete o Installation of exterior walk-in cooler and all required site alterations, and utility deconflictions o Custom Model No. WALK IN COOLER/FREEZER o Actual Ext. Dimensions: 9' - 0" X 30' - 0" X 7' - 6" high o Freezer Int. Dimensions: 8' - 4" X 9' - 0" X 6' - 10.25" high -10 F Freezer o Beer Cooler Int. Dimensions: 8' - 4" X 20' - 0" X 7' - 2" high 35 F Beer Cooler o Floor Finish Freezer: Foamed-in place 4'' Urethane floor panels .100 o Smooth Aluminum o Beer Cooler: Floorless on Aluminum Angle o Metal Finishes o Exposed Exterior: Designer Color 24 Ga. Sm. Galv. o Unexposed Exterior: Designer Color 24 Ga. Sm. Galv. o Interior Walls: 26 ga. white stucco galv. Steel o Interior Ceiling: 26 ga. white stucco galv. steel o All panels are NSF 4" foamed-in-place urethane, UL classified with flame spread rating of 20. o 36" X 77" flush mount magnetic in fitting door with cam-rise hinges, o padlockable deadbolt handle (exterior doors only), closer, brushed hardware, energy saving door frame heater wire, vapor proof light & switch with pilot light. o Walk-In Accessories Qty. o Description 1 HPRV #1827 (3" diam.) o 1 Vinyl Membrane Rain Roof, Flat (201-400 sq ft), Two Room o 1 One-Way Pitch (Sloped 1/4"/ft.) (201-400 sq ft), Two Room o 1 Electronically Sealed Engineering Plans up to 12' x 30' w/o internal steel posts/beam (State of Fla.) o 30 Hurricane Code Floor Angle (for walk-ins with floor) o 1 Outdoor Weather Cover for Intelligent Controller (IC) o 1 Floor Ramp, Interior (24" deep) for up to 42" door o 1 Door Rain Cap o 4 LED Light Fixture, Cooler & Freezer, 48" 2-lamp (-40F or higher operating temp.) o 4 Door Kickplate, 1/10" aluminum treadplate, 36" High, <37" Door o 2 CCI Clear Vu 2-pc Swing Door Curtain, 34" (or 36") x 80" opening o 1 Vision Window, 14" x 14" heated o 2 Trim Strips, 3" x 3", Designer Color finish o 53 Hurricane Code Floor Angle (replacing std. angle) 2 Upgrade to Intelligent Controller (IC) to Enable Dry Contacts & 3-Way Lighting 2 25 ft. extended probe for IC/IC+ o Hermetic scroll air cooled refrigeration system -10 F Freezer o 208/230/60/3 o Includes standard low profile evaporator coil o Includes 5-Year Compressor Warranty o Hermetic scroll air cooled refrigeration system 35 F Beer Cooler o 208/230/60/3 o Includes standard low profile evaporator coil o Includes 5-Year Compressor Warranty o Refrigeration Accessories o 2 UL Listed Outdoor Weather Cover, Hinged 2 Stand for U.L. Cover (18" high) o Outfit with shelving throughout Walk In Cooler o Removal of existing fence and re-installation of fence o Electric as required o Drain lines as required o Removal of existing NuCo2 system, beer lines, and glycol system and the re-installation of new NUCo2 system, beer lines, and glycol system (the equipment purchases and work will be performed by the current vendor) o Installation of structural safety barricades around the project site prior to project commencement. Removal of safety barricades upon "final acceptance" of the project by BBRD. o Any other work required by permitting agencies Final determination of specifications will be made at the mandatory pre-submittal site inspection since the outdoor space available will determine the size of the walk-in cooler and required equipment. A performance bond is not required to be included in the proposal.BBRD reserves the right to reject any or all bids/proposals, to cancel or withdraw this bids/proposals at any time or take any other such actions that may be deemed in the best interest of the District.

Award

Municipal

$127,500.00

Public - County

Renovation

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

3

Subscribe For Documents

11 Record(s)

Subscribe for All Details

Trades Specified

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet

Find More Local Projects

Within 75 Miles of This Project
206
Active Projects
104
Bidding Soon
1,329
All Active Projects
0
Updated Recently

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

June 27, 2025

July 28, 2025

Project location map

625 Barefoot Blvd, Micco, FL

Related To This Project


Recently Viewed

Fuel growth with access to the bidding project info your business needs.

Full details, including key contact information, important dates, plans and specifications, on over 500,000 Projects including 5000 updated daily available to subscribers.